Implementation Of A New Technique For Magnetic Improvised Explosive Device Detection

Mahmood, Hamzah Naser (2018) Implementation Of A New Technique For Magnetic Improvised Explosive Device Detection. Masters thesis, Universiti Sains Malaysia.

[img]
Preview
PDF
Download (174kB) | Preview

Abstract

Peranti Bermagnet Bahan Letupan yang Dinaik Taraf (IED) yang juga dikenali sebagai sejenis bom melekit adalah alat yang mudah dibina namun memberi kesan yang boleh membawa maut. Oleh itu, penyelidikan ini menekankan pengehadan bagi kaedah-kaedah yang telah dicadangkan untuk mengatasi ancaman ini dan bahayanya yang semakin meningkat dengan menunjukkan kekurangan persediaan eksperimentasi secara sistematik, ketiadaan nilai komersial selain kemungkinan yang tidak dapat dielakkan untuk merisikokan keselamatan kakitangan semasa mengendalikan beberapa sistem yang disebabkan oleh kekurangan automasi atau tidak menjadi mudah alih. Penyelidikan ini telah menyiasat satu pengesan bergred pengguna yang mampu mengesan satu medan bermagnet dalam ± 8 Gauss. Pengesan ini digunakan untuk mengesan magnet untuk meniru IED bermagnet. Magnet-magnet tersebut adalah dua bahan yang berlainan (berbeza dalam kekuatan ketumpatan medan magnet) dengan jumlah kiraan yang berbeza, dan ia telah digunakan untuk menghasilkan kemungkinan senario yang berbeza. Magnet-magnet tersebut adalah Neodimium dan Seramik dengan purata ketumpatan fluks masing-masing sebanyak 12,500 dan 2,500 Gauss. Tambahan pula, satu teknik baru telah dibangunkan dan dilaksanakan sebagai satu teknik pengujian sistematik yang praktikal berdasarkan kawasan eksperimen yang bergrid, yang mana ia adalah bersaiz sel individu yang sesuai dengan ancaman yang disifatkan. Teknik baru ini dinilai menggunakan pengesan dengan tujuan untuk meneroka sejauh mana kebolehannya untuk pengesanan IED bermagnet. Sebagai keputusannya, ia telah menghasilkan keputusan dalam bentuk yang mudah dikesan dan membuka jalan kepada analisis selanjutnya. Keputusan teknik baru ini telah mendedahkan bahawa kemungkinan pengesanan ancaman menggunakan pengesan yang digunakan bersama-sama dengan magnet di bawah kes-kes tertentu, di mana kes terburuk adalah ~ 181.4% kemungkinan pengesanan manakala kes terbaik adalah sehingga ~ 1666.7%, pada jarak 8.5 cm jauh dari pengesan. Walau bagaimanapun, bermula dari jarak 17 cm jauh dari pengesan dan seterusnya, bilangan nombor magnet yang berbeza dari dua bahan berbeza mula menyumbang secara berbeza kepada variasi bacaan. Nilai-nilai pembezaannya adalah serendah ~ 0.72% hingga ~ 2.1% pada jarak masing-masing 42.5 cm hingga 51 cm untuk bahan seramik, manakala bahan Neodimium adalah serendah ~ 2.3% dan 2.5% pada jarak masing–masing 59.5 cm dan 42.5 cm. Akhirnya, penyelidikan ini akhirnya mencadangkan kebolehpasarannya berbanding dengan yang lain yang menjadikannya sebagai alasan kukuh untuk kajian masa hadapan yang berkaitan dengan pembangunan sistem pengesanan bermagnet IED yang melibatkan kos rendah dan mudah alih. _______________________________________________________________________________________________________ The Magnetic Improvised Explosive Devices (IEDs), also commonly known as a type of a sticky bombs, are simply constructed devices yet very lethal. Consequently, this research highlights the limitations of methods that have been proposed to counteract this threat and its ever-increasing danger by indicating their lack of systematic experimentation setups, commercial unavailability in addition to the inevitable possibility of risking personnel safety while operating some systems due to lack of automation or being not portable. The research has investigated a consumergrade sensor that is capable of sensing a magnetic field ranging within ±8 Gauss. The sensor is employed for sensing magnets to mimic the magnetic IEDs. The magnets are of two different materials (contrasting in magnetic field density strength) with different counts, and they were used to develop different possibilities of scenarios. The magnets are Neodymium and Ceramic with an average flux density of 12,500 and 2,500 Gauss respectively. Furthermore, a new technique has been developed and implemented as a practical systematic testing technique based on gridded experimental area, which has an individual cell size corresponding to a characterized threat. This new technique is evaluated using the employed sensor with the purpose of exploring its extent of employability for Magnetic IEDs detection. As a result, it has allowed the representation of the results in a traceable manner and paved the way for further analysis. The results of the new technique have revealed that the chances of threat detection using the employed sensor in conjunction with magnets under defined cases, where the worst case there is a ~ 181.4% chance of detection whereas the best case it could be as high as ~ 1666.7%, at a distance of 8.5 cm away from the sensor. However, starting from 17 cm distance from the sensor onwards, different number of magnets of the two different materials begins to contribute differently into readings variations. Its extent of distinguishability values is as low as ~ 0.72 % to ~ 2.1 % at a distance of 42.5 cm to 51 cm respectively for Ceramic material, while the Neodymium material is as low as ~2.3% and 2.5% at a distance of 59.5 cm and 42.5 cm respectively. Finally, the research eventually recommended its employability in comparison with others laying the ground for future studies concerned with developing low-cost, portable Magnetic IEDs detection systems.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Full text is available at http://irplus.eng.usm.my:8080/ir_plus/institutionalPublicationPublicView.action?institutionalItemId=4613
Subjects: T Technology
T Technology > TK Electrical Engineering. Electronics. Nuclear Engineering > TK1001-1841 Production of electric energy or power. Powerplants. Central stations
Divisions: Kampus Kejuruteraan (Engineering Campus) > Pusat Pengajian Kejuruteraaan Elektrik & Elektronik (School of Electrical & Electronic Engineering) > Thesis
Depositing User: Mr Mohd Jasnizam Mohd Salleh
Date Deposited: 06 May 2019 04:02
Last Modified: 06 May 2019 04:02
URI: http://eprints.usm.my/id/eprint/44279

Actions (login required)

View Item View Item
Share