Moderator, Collimator And Shielding Studies For Bnct Research At Malaysian Nuclear Agency

Mohd Solleh, Mohd Rafi (2016) Moderator, Collimator And Shielding Studies For Bnct Research At Malaysian Nuclear Agency. PhD thesis, Universiti Sains Malaysia.

[img]
Preview
PDF
Download (643kB) | Preview

Abstract

Objektif penyelidikan ini adalah untuk mengkaji pengoptimunan susun atur bagi kemudahan Boron Neutron Capture Therapy (BNCT) pada garisan alur neutron yang melalui kolum termal pada Reaktor TRIGA MARK II Malaysia. Belum ada penyelidikan sebegini dilakukan di kolum termal tersebut dan ciri setiap reaktor TRIGA adalah berbeza. Ciri alur neutron yang diperlukan adalah neutron yang bertenaga terma dengan fluk sebanyak 109 cm-2s-1 dan alurnya berdiameter 15 cm. Kolimator, moderator dan komponen perisaian bersama teras reaktor dan kolum termal disimulasi menggunakan Monte Carlo N-Particle Transport Code. Fluk neutron dan foton dikira bersama dengan tenaga masing-masing menggunakan perisian yang sama. Selepas itu kolimator dan perisai telah dibina. Polyethylene dan air telah digunakan sebagai perisai neutron laju dan neutron epiterma. Plumbum pula digunakan sebagai perisai sinar gama. Kolimator diperbuat dari paip polyethylene berdiameter 8 cm dan disikan dengan lilin. Pengukuran neutron dan sinar gama di dalam Graphite Stringer tengah (G7) pada kolum termal telah dilakukan menggunakan pengesan TLD. The objective of this research is to optimally study an arrangement for BNCT facility at a beam line through the thermal column of Malaysian TRIGA MARK II Reactor. There is no similar research had been done at this thermal column and all TRIGA reactors have different characteristics. The characteristics of the neutron beam needed are thermal neutron with a flux of 109 cm-2s-1 and the diameter of the beam is 15 cm. Collimator, moderator and shielding components with reactor core and thermal column were simulated with Monte Carlo N-Particle Transport Code. Fluxes of neutron and photon were calculated together with their energies with the same software. After that, collimator and shielding are fabricated. For fast and epithermal neutron shielding, a polyethylene and water were used. For gamma-ray shielding, lead was used. The collimator is made from polyethylene pipe with 8 cm of diameter filled with paraffin. Neutron and gamma-ray measurement in a Central Graphite Stringer (G7) of thermal column was done with TLD detectors.

Item Type: Thesis (PhD)
Subjects: Q Science > QC Physics > QC1 Physics (General)
Divisions: Pusat Pengajian Sains Fizik (School of Physics) > Thesis
Depositing User: Mr Noorazilan Noordin
Date Deposited: 09 Jan 2017 04:37
Last Modified: 12 Apr 2019 05:25
URI: http://eprints.usm.my/id/eprint/31478

Actions (login required)

View Item View Item
Share