Oil Height Determination From Capacitance Tomography Measurements Using Neural Network.

Mohamad-Saleh, J and Abdul-Salam, R. (2004) Oil Height Determination From Capacitance Tomography Measurements Using Neural Network. In: ACIT'2004 - 5th International Arab Conference on Information Technology, 2004.

[img]
Preview
PDF - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
2028Kb

Abstract

This paper presents a "direct" method to gas-oil interface level determination using an artificial neural network approach based on Electrical Capacitance Tomography (ECT) measurements. "Direct" here means that the gas-oil interface levels are obtained directly from the ECT measurements without recourse to image reconstruction. The preliminary work models a separation tank that is filled with gas and oil.