Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study

Lee, Mohammad Faizal Nikman (2017) Comparison of varus malalignment in unstable extracapsular proximal femur fracture between proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) : a retrospective study. Masters thesis, Universiti Sains Malaysia.

[img]
Preview
PDF - Submitted Version
Download (646kB) | Preview

Abstract

Unstable fractures of proximal femur of the pertrochanteric and subtrochanteric region are challenging injuries due to the high loads transmission across the affected part of the bone to the hip joint. The selection of the implants remained controversial but many studies favouring intramedullary implants for fractures’ fixation. The nature of the bone with strong muscular action with high compressive forces acting medially are responsible for intraoperative and postoperative complications and difficulties. Varus malalignment is one of the commonest complication found in proximal femur fractures. This study was done to evaluate the incidence of varus malalignment in unstable extracapsular proximal femur fracture. METHODS: 60 patients with closed unstable fracture of proximal femur involving pertrochanteric and subtrochanteric region were subjected into 2 groups of fixation and retrospectively evaluated. 30 patients each for proximal femoral nail antirotation (PFNA) and proximal femoral locking plate (PFLCP) group were operated. Incidence of varus malalignment immediately post operation, quality of fracture’s reduction immediately post operation and implant’s sustainability of fracture’s reduction at 6 months post operation were analyzed for both groups. RESULTS: Immediately after fracture’s fixation, incidence of varus malalignment was higher in PFLCP group (23.3%) compared to PFNA group (13.3%). However the quality of fracture’s reduction immediately post operation and implant’s sustainability of fracture’s reduction at 6 months between both implants were not statistically significant. CONCLUSIONS: PFLCP offered comparable result as PFNA for osteosysnthesis of unstable extracapsular proximal femur fracture in term of varus malalignment on immediate and 6 months post operation.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Bone malalignment
Subjects: R Medicine > RC Internal medicine > RC31-1245 Internal medicine
Divisions: Kampus Kesihatan (Health Campus) > Pusat Pengajian Sains Perubatan (School of Medical Sciences) > Thesis
Depositing User: Mr Abdul Hadi Mohammad
Date Deposited: 29 Nov 2018 07:00
Last Modified: 12 Apr 2019 05:25
URI: http://eprints.usm.my/id/eprint/43075

Actions (login required)

View Item View Item
Share